Client Area
Register here
ORDER INFORMATION
- Marcus accepts national and international orders.- Outstanding Customer Service
- Shipping Same-day or on Next Business Day

- We appreciate your business

Marcus Transformers Catalog
Search Results
MS / MSH - Single Phase
General Purpose Transformer
For installation in indoor locations with a clean, dust free and chemical - free air circulation. Provides a degree of protection against incidental contact by non-authorized personnel
General Purpose Transformer
For installation in indoor locations with a clean, dust free and chemical - free air circulation. Provides a degree of protection against incidental contact by non-authorized personnel
MT / MTH - Three Phase
General Purpose Transformer
For installation in indoor locations with a clean, dust free and chemical - free air circulation. Provides a degree of protection against incidental contact by non-authorized personnel
General Purpose Transformer
For installation in indoor locations with a clean, dust free and chemical - free air circulation. Provides a degree of protection against incidental contact by non-authorized personnel
AMTH - Three Phase Aluminum
For installation in indoor or outdoor locations with clean and chemical - free air circulation. Provides protection against rain, sleet or snow and incidental contact by non-authorized personnel
For installation in indoor or outdoor locations with clean and chemical - free air circulation. Provides protection against rain, sleet or snow and incidental contact by non-authorized personnel
- 3R enclosure
- Does not require fireproof vaults or special installations
- Lightweight with no liquids to inspect
- May be installed close to the load to reduce wiring runs
- Used to change supply voltages to voltages required by lighting and various types of equipment
- Commonly used for inductive and resistive loads such as motors and heating
- Wall mount brackets 15KVA, 30KVA, 45KVA
MK / MKH - Three Phase K-Factor
For Non-linear Loads
Specifically designed and engineered for safe, efficient handling of non-linear loads created by computers, video display terminals, electronic ballasts, fax and copy machines and programmable controllers.
For Non-linear Loads
Specifically designed and engineered for safe, efficient handling of non-linear loads created by computers, video display terminals, electronic ballasts, fax and copy machines and programmable controllers.
MKS / MKSH - Single Phase K-Factor
Specifically designed and engineered for safe, efficient handling of non-linear loads created by computers, video display terminals, electronic ballasts, fax and copy machines and programmable controllers.
Specifically designed and engineered for safe, efficient handling of non-linear loads created by computers, video display terminals, electronic ballasts, fax and copy machines and programmable controllers.
MDI / MDIH - Three Phase Drive Isolation
For use with AC and DC adjustable speed drives which generate mechanical stresses and harmonic currrents beyond the design criteria of normal general purpose transformers.
For use with AC and DC adjustable speed drives which generate mechanical stresses and harmonic currrents beyond the design criteria of normal general purpose transformers.
MSWP / MSWPH - Single Phase Outdoor
Enclosure 3R provides superior protection from rain, sleet or snow.
Also suitable for indoor use in tunnels, mines and pumping stations where dripping and splashing water is a problem.
Enclosure 3R provides superior protection from rain, sleet or snow.
Also suitable for indoor use in tunnels, mines and pumping stations where dripping and splashing water is a problem.
MTWP / MTWPH - Three Phase Outdoor
Enclosure type 3R provides superior protection from rain, sleet or snow. Also suitable for indoor use in tunnels, mines and pumping stations where drilling and splashing water is a problem.
Enclosure type 3R provides superior protection from rain, sleet or snow. Also suitable for indoor use in tunnels, mines and pumping stations where drilling and splashing water is a problem.
MTWP-SCR - Three Phase Outdoor Enhanced
Additional Protective Mesh Enhances the NEMA 3R Feature.
Ventilated, Dry-type transformers with weather buffer screens
Enclosure type 3R provides superior protection from rain, sleet or snow. Also suitable for indoor use in tunnels, mines and pumping stations where drilling and splashing water is a problem.
Restricts entry of blowing rain or snow without affecting normal cooling air flow
Lower costs and easier installation than sealed transformers
Lighter weight than non-ventilated and resin encapsulated alternatives
Perfect for open areas where exposure to wind, rain and snow is a problem
Typical Applications:
Roof Tops
Fresh water lake front docks
Pool Areas
Additional Protective Mesh Enhances the NEMA 3R Feature.
Ventilated, Dry-type transformers with weather buffer screens
Enclosure type 3R provides superior protection from rain, sleet or snow. Also suitable for indoor use in tunnels, mines and pumping stations where drilling and splashing water is a problem.
Restricts entry of blowing rain or snow without affecting normal cooling air flow
Lower costs and easier installation than sealed transformers
Lighter weight than non-ventilated and resin encapsulated alternatives
Perfect for open areas where exposure to wind, rain and snow is a problem
Typical Applications:
Roof Tops
Fresh water lake front docks
Pool Areas
RES - Single Phase Epoxy Encapsulated
Designed to withstand the harshest indoor and outdoor applications, our epoxy encapulated transformers are completely enclosed in Type 3R enclosures and provide safe, reliable protection from corrosive atmospheres, hazardous gases, dust and moisture. For use in pulp and paper plants, steel mills, petrochemical plants, food processing facilities, breweries, mines, marine and shipboard installations. Certified for Class 1, Division 2 group A-D locations with a temperature classification of T3C, T4 and T5. Available with 4X stainless steel enclosures.
Designed to withstand the harshest indoor and outdoor applications, our epoxy encapulated transformers are completely enclosed in Type 3R enclosures and provide safe, reliable protection from corrosive atmospheres, hazardous gases, dust and moisture. For use in pulp and paper plants, steel mills, petrochemical plants, food processing facilities, breweries, mines, marine and shipboard installations. Certified for Class 1, Division 2 group A-D locations with a temperature classification of T3C, T4 and T5. Available with 4X stainless steel enclosures.
RET - Three Phase Epoxy Encapsulated
Designed to withstand the harshest indoor and outdoor applications, our epoxy encapulated transformers are completely enclosed in Type 3R enclosures and provide safe, reliable protection from corrosive atmospheres, hazardous gases, dust and moisture. For use in pulp and paper plants, steel mills, petrochemical plants, food processing facilities, breweries, mines, marine and shipboard installations. Certified for Class 1, Division 2 group A-D locations with a temperature classification of T3C, T4 and T5. Available with 4X stainless steel enclosures.
Designed to withstand the harshest indoor and outdoor applications, our epoxy encapulated transformers are completely enclosed in Type 3R enclosures and provide safe, reliable protection from corrosive atmospheres, hazardous gases, dust and moisture. For use in pulp and paper plants, steel mills, petrochemical plants, food processing facilities, breweries, mines, marine and shipboard installations. Certified for Class 1, Division 2 group A-D locations with a temperature classification of T3C, T4 and T5. Available with 4X stainless steel enclosures.
MTWPCD / MTWPCDH - Three Phase Outdoor Ventilated
The Marcus model-CD (MTWPCD) transformer is for use in applications where Class 1 Division 2 is required. It is designed with a Type 3R enclosure and is built to withstand locations with hazardous gases, corrosive atmospheres and airborne pollutants. Typical Applications include: Mining, petrochemical and pulp & paper installations. Certified for Class 1, Division 2 group A-D locations with a temperature classification of T3C, T4 and T5. The benefits of the model-CD over the epoxy encapsulated transformer is in its lighter weight and lower cost.
The Marcus model-CD (MTWPCD) transformer is for use in applications where Class 1 Division 2 is required. It is designed with a Type 3R enclosure and is built to withstand locations with hazardous gases, corrosive atmospheres and airborne pollutants. Typical Applications include: Mining, petrochemical and pulp & paper installations. Certified for Class 1, Division 2 group A-D locations with a temperature classification of T3C, T4 and T5. The benefits of the model-CD over the epoxy encapsulated transformer is in its lighter weight and lower cost.
MTZ / MTZH- Marcus Harmonic Mitigating (Harmonic Sweeper)
Where to use Harmonic Sweeper™ (stand alone or in parallel with Marcus MT/MTH models)
In commercial, institutional and industrial buildings
With UPS or special generator groups
Industrial rectifier
PWM drives for elevators
UV filtering lights
Electronic ballast lighting
Where to use Harmonic Sweeper™ (stand alone or in parallel with Marcus MT/MTH models)
In commercial, institutional and industrial buildings
With UPS or special generator groups
Industrial rectifier
PWM drives for elevators
UV filtering lights
Electronic ballast lighting
MTD / MTDH - Double Harmonic Mitigating
The DOUBLE HARMONIC SWEEPERTM gives you the opportunity to treat the 3rd, 5th &
7th harmonics with a single transformer having a double secondary with both 0 degree and 30 degree phase displacement. Furthermore the DOUBLE HARMONIC SWEEPER has a low impedance with low voltage distortion, because the triplen harmonics are cancelled in the magnetic circuit and do not circulate in the primary winding. The 5th and 7th harmonics are eliminated due to the phase shift angle of 30° between the two outputs .
This harmonic cancellation transformer may be used with loads having a high content of 3rd,
5th & 7th harmonics like line-neutral rectifiers. The DOUBLE HARMONIC SWEEPER™ is an effective double phase shift transformer (similar to a delta/double zig-zag). Simply install the unit, split and equally balance the non-linear load between the double outputs, and the harmonic content will be effectively reduced.
The DOUBLE HARMONIC SWEEPERTM gives you the opportunity to treat the 3rd, 5th &
7th harmonics with a single transformer having a double secondary with both 0 degree and 30 degree phase displacement. Furthermore the DOUBLE HARMONIC SWEEPER has a low impedance with low voltage distortion, because the triplen harmonics are cancelled in the magnetic circuit and do not circulate in the primary winding. The 5th and 7th harmonics are eliminated due to the phase shift angle of 30° between the two outputs .
This harmonic cancellation transformer may be used with loads having a high content of 3rd,
5th & 7th harmonics like line-neutral rectifiers. The DOUBLE HARMONIC SWEEPER™ is an effective double phase shift transformer (similar to a delta/double zig-zag). Simply install the unit, split and equally balance the non-linear load between the double outputs, and the harmonic content will be effectively reduced.
MS-CC / MSH-CC Single Phase Open Type Core & Coil
Designed for installation within cabinets where no additional individual enclosure is required. Suitable for feeding MCC's and switchgear where space is at a premium. hadoop training in chennai where to buy phentermine
Designed for installation within cabinets where no additional individual enclosure is required. Suitable for feeding MCC's and switchgear where space is at a premium. hadoop training in chennai where to buy phentermine
MO - Single Phase Open Style
Indoor type open style / single phase [MO]
Operating Frequency: 60 Hz (50/60 Hz available on some models)
Insulation : 130 deg c: (25-1000 VA) - Class B 80 deg c Temp Rise
155 deg c: (1500-7500 VA) - Class F 100 deg c Temp Rise
Sound level: less than 40 db
Polarity: Additive
Indoor type open style / single phase [MO]
Operating Frequency: 60 Hz (50/60 Hz available on some models)
Insulation : 130 deg c: (25-1000 VA) - Class B 80 deg c Temp Rise
155 deg c: (1500-7500 VA) - Class F 100 deg c Temp Rise
Sound level: less than 40 db
Polarity: Additive
MC - Single Phase Closed Type
Indoor Type Enclosed style / single phase
Operating Frequency: 60 Hz (50Hz avaiable on some models)
Insulation: 130 deg c (50-1000 VA) - Class B 95 deg c Temp Rise
155 deg c (1500-5000 VA) - Class F 115 deg c Temp Rise
Sound Level: less than 40 db
Polarity: Additive
Indoor Type Enclosed style / single phase
Operating Frequency: 60 Hz (50Hz avaiable on some models)
Insulation: 130 deg c (50-1000 VA) - Class B 95 deg c Temp Rise
155 deg c (1500-5000 VA) - Class F 115 deg c Temp Rise
Sound Level: less than 40 db
Polarity: Additive
MT-CC / MTH-CC - Three Phase Open Type Core & Coil
Designed for installation within cabinets where no additional individual enclosure is required. Suitable for feeding MCC's and switchgear where space is at a premium.
Designed for installation within cabinets where no additional individual enclosure is required. Suitable for feeding MCC's and switchgear where space is at a premium.
MOS- Single Phase Fusible Open Type w/ Fuseblock Premounted
Indoor rated open type transformer with premounted fuseblock / single phase [MOS[
Operating Frequency: 60 Hz (50/60 Hz available on some models)
Insulation : 130 deg c: (25-1000 VA) - Class B 80 deg c Temp Rise
155 deg c: (1500-7500 VA) - Class F 100 deg c Temp Rise
Sound level: less than 40 db
Polarity: Additive
Indoor rated open type transformer with premounted fuseblock / single phase [MOS[
Operating Frequency: 60 Hz (50/60 Hz available on some models)
Insulation : 130 deg c: (25-1000 VA) - Class B 80 deg c Temp Rise
155 deg c: (1500-7500 VA) - Class F 100 deg c Temp Rise
Sound level: less than 40 db
Polarity: Additive
MTB - Single Phase Open Style (fuse block use)
Open style transformer designed for use with fuse block
Operating Frequency: 60 Hz (50Hz avaiable on some models)
Insulation: 130 deg c (25-1000 VA)
80 deg c Temp Rise Class B
Sound Level: less than 40 db
Polarity: Additive
Open style transformer designed for use with fuse block
Operating Frequency: 60 Hz (50Hz avaiable on some models)
Insulation: 130 deg c (25-1000 VA)
80 deg c Temp Rise Class B
Sound Level: less than 40 db
Polarity: Additive
TPO - Three Phase Open Type
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: Class F (155 deg c) (Type TPO 100 deg c)
Sound level: Less than 40 db
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: Class F (155 deg c) (Type TPO 100 deg c)
Sound level: Less than 40 db
AC&AS - Single Phase Auto Closed Type
Output VA range: 0.5-20 (Series ACK), 0.5-20 (Series ASK), 0.5-7.5 (Series ACM)
Operating Frequency: 50/60 Hz (ACM), 60 Hz (Series ACK), 60 Hz (Series ASK)
Insulation: 130 deg c: Series ACK (0.5-10 KVA)
Series ASK (0.5-7.5 KVA)
Series ACM (0.5-2 KVA)
155 deg c: Series ASK (10-20 KVA)
Series ACM (3-7.5 KVA)
Series ACK (15-20 KVA)
Sound Level: :Less than 40 dB
Output VA range: 0.5-20 (Series ACK), 0.5-20 (Series ASK), 0.5-7.5 (Series ACM)
Operating Frequency: 50/60 Hz (ACM), 60 Hz (Series ACK), 60 Hz (Series ASK)
Insulation: 130 deg c: Series ACK (0.5-10 KVA)
Series ASK (0.5-7.5 KVA)
Series ACM (0.5-2 KVA)
155 deg c: Series ASK (10-20 KVA)
Series ACM (3-7.5 KVA)
Series ACK (15-20 KVA)
Sound Level: :Less than 40 dB
TPOA - Three Phase Auto Open Type
• Marcus Type TPOA three-phase auto transformers provide a quick and simple way to convert standard supply voltages to those special voltages required by small loads and fractional motors.
• These compact open-type copper transformers are Y-connected and are fitted with clearly labelled fiberglass terminal boards with solidly fixed connection studs for easy installation.
• Unlike the use of multiple unit buck-boost arrangements, there is no complicated internal wiring necessary and no conversion charts to decipher.
• As with all auto transformer installations, the loads are not isolated from the line source and caution should be exercised when there are electronics or computer controls present.
• Available in a full range of voltage combinations up to 3KVA.
• Marcus Type TPOA three-phase auto transformers provide a quick and simple way to convert standard supply voltages to those special voltages required by small loads and fractional motors.
• These compact open-type copper transformers are Y-connected and are fitted with clearly labelled fiberglass terminal boards with solidly fixed connection studs for easy installation.
• Unlike the use of multiple unit buck-boost arrangements, there is no complicated internal wiring necessary and no conversion charts to decipher.
• As with all auto transformer installations, the loads are not isolated from the line source and caution should be exercised when there are electronics or computer controls present.
• Available in a full range of voltage combinations up to 3KVA.
MC - Buck/Boost Wiring
• Buck-boost transformers are small single phase transformers designed to reduce (buck) or raise (boost) the line voltage.
• The most common example is boosting 208V to 230V for motor load operation.
• Buck/Boosts are standard single phase transformers with primary voltages of 120/240 and secondary voltages of 12/24 or 16/32.
• They are available in sizes ranging 50VA to 5kva.
Applications
• When supply voltages are consistently too high or too low, the equipment fails to operate at maximum efficiency.
• Anytime you have a lower than standard voltage, equipment failure or damage can result.
• Efficient operation of electrical equipment requires that line voltage be at or near the nameplate rating of the equipment. In order to match line voltage with equipment voltage, buck-boost transformers provide the most convenient and least expensive method.
• Do not use buck-boost transformers to solve a fluctuating voltage problem.
Buck Boost Selection Guide (3MB, PDF)• The most common example is boosting 208V to 230V for motor load operation.
• Buck/Boosts are standard single phase transformers with primary voltages of 120/240 and secondary voltages of 12/24 or 16/32.
• They are available in sizes ranging 50VA to 5kva.
Applications
• When supply voltages are consistently too high or too low, the equipment fails to operate at maximum efficiency.
• Anytime you have a lower than standard voltage, equipment failure or damage can result.
• Efficient operation of electrical equipment requires that line voltage be at or near the nameplate rating of the equipment. In order to match line voltage with equipment voltage, buck-boost transformers provide the most convenient and least expensive method.
• Do not use buck-boost transformers to solve a fluctuating voltage problem.
TPCA - Three Phase Control Autotransformers
• Three phase control autotransformers offer a fast and simple way to convert standard line voltages to those required for small loads and small motors.
• These compact, NEMA-1 enclosed autotransformers are Y-connected and come equipped with clearly labeled fiberglass terminal boards with solidly fixed terminals in order to facilitate the installation.
• Unlike connecting multiple buck-boost type transformers, there is no complicated internal wiring to carry out nor any conversion charts to decipher.
• In common with all other autotransformer installations, the loads are not isolated from the line and caution must be taken to ensure the load doesn’t contain any electronic controls or computer loads.
• Available up to 3000VA (3kVA) with a full range of line and load voltages.
• Three phase control autotransformers offer a fast and simple way to convert standard line voltages to those required for small loads and small motors.
• These compact, NEMA-1 enclosed autotransformers are Y-connected and come equipped with clearly labeled fiberglass terminal boards with solidly fixed terminals in order to facilitate the installation.
• Unlike connecting multiple buck-boost type transformers, there is no complicated internal wiring to carry out nor any conversion charts to decipher.
• In common with all other autotransformer installations, the loads are not isolated from the line and caution must be taken to ensure the load doesn’t contain any electronic controls or computer loads.
• Available up to 3000VA (3kVA) with a full range of line and load voltages.
MEC - Single Phase Epoxy Encapsulated Control
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: 130 deg c Class B (25 VA - 750 VA)
155 deg c Class F (1000 VA - 2000 VA)
Sound Level:Less than 40 dB
Polarity: Additive
For installation in locations where exposureto the atmosphere could damage the core and coils. Elements are completely enclosed in type 3R and 12 enclosures to ensure safe and trouble-free service in damp, corrosive and suty locations. Suitable for use in refineries, mines, pulp and paper plants, mills and marine environments.
Suitable for Class 1, Division 2 locations
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: 130 deg c Class B (25 VA - 750 VA)
155 deg c Class F (1000 VA - 2000 VA)
Sound Level:Less than 40 dB
Polarity: Additive
For installation in locations where exposureto the atmosphere could damage the core and coils. Elements are completely enclosed in type 3R and 12 enclosures to ensure safe and trouble-free service in damp, corrosive and suty locations. Suitable for use in refineries, mines, pulp and paper plants, mills and marine environments.
Suitable for Class 1, Division 2 locations
MLR - Line Reactor Open Type
Rated Parameters: Nominal Inductance +/- 10% tolerance at rated current. 95% of nominal inductance at 150% rated current
Operating Frequency: 60 Hz Fundamental Current maximum
Insulation: Class F (155 deg c), but with low temperature rise
Sound Level: 2 - 25 amps <= 55 dB; 35 - 110 amps <= 60dB
Rated Parameters: Nominal Inductance +/- 10% tolerance at rated current. 95% of nominal inductance at 150% rated current
Operating Frequency: 60 Hz Fundamental Current maximum
Insulation: Class F (155 deg c), but with low temperature rise
Sound Level: 2 - 25 amps <= 55 dB; 35 - 110 amps <= 60dB
MLRC - Line Reactor Closed Type
Rated Parameters: Nominal Inductance +/- 10% tolerance at rated current. 95% of nominal inductance at 150% rated current
Operating Frequency: 60 Hz Fundamental Current maximum
Insulation: Class F (155 deg c), but with low temperature rise
Sound Level: 2 - 25 amps <= 55 dB; 35 - 110 amps <= 60dB
Rated Parameters: Nominal Inductance +/- 10% tolerance at rated current. 95% of nominal inductance at 150% rated current
Operating Frequency: 60 Hz Fundamental Current maximum
Insulation: Class F (155 deg c), but with low temperature rise
Sound Level: 2 - 25 amps <= 55 dB; 35 - 110 amps <= 60dB
MET - Compact Solid State Electronic Transformers
Electronic Transformer for halogen lamps & L.E.D Applications
NEW DESIGN ALLOWS FOR USE WITH L.E.D LIGHTING!
**Quantity discounts available**
The MET series provides control of low voltage sources with a standard 120 volts dimmer or switch. Compatible with most incandescent and electronic type dimmers, units have complete zero to full power gradient capacity. Significant size/weight reductions open new design and flexibility.
New design allows for use with L.E.D lighting!
For use in store display counters and gas fireplace enhancement.
Fuse Protected Electronic Transformer
Model:MET-60 Input: 120V / Output: 11.5v
Operating Frequency: 60 Hz
Load: 60 Watts max. / 3 Watts min.
Size: 2.75"(60mm) x 1.44"(36mm) x 1.13"(29mm)
Thermal Cut Off Protected Transformer
Model: MET-75-1
Input: 120V / Output: 11.5v
Operating Frequency: 60 Hz
Load: 80 Watts max. / 3 Watts min.
Size: 3.56"(90mm) x 1.25"(32mm) x 0.97"(25mm)
Thermal Cut Off Protected Transformer
Model: ET-150-12-1
Input: 120V / Output: 11.5v
Operating Frequency: 60 Hz
Load: 150 Watts max. / 10 Watts min.
Size: 4.03"(103mm) x 1.41"(36mm) x 1.06"(27mm)
Electronic Transformer for halogen lamps & L.E.D Applications
NEW DESIGN ALLOWS FOR USE WITH L.E.D LIGHTING!
**Quantity discounts available**
The MET series provides control of low voltage sources with a standard 120 volts dimmer or switch. Compatible with most incandescent and electronic type dimmers, units have complete zero to full power gradient capacity. Significant size/weight reductions open new design and flexibility.
New design allows for use with L.E.D lighting!
For use in store display counters and gas fireplace enhancement.
Fuse Protected Electronic Transformer
Model:MET-60 Input: 120V / Output: 11.5v
Operating Frequency: 60 Hz
Load: 60 Watts max. / 3 Watts min.
Size: 2.75"(60mm) x 1.44"(36mm) x 1.13"(29mm)
Thermal Cut Off Protected Transformer
Model: MET-75-1
Input: 120V / Output: 11.5v
Operating Frequency: 60 Hz
Load: 80 Watts max. / 3 Watts min.
Size: 3.56"(90mm) x 1.25"(32mm) x 0.97"(25mm)
Thermal Cut Off Protected Transformer
Model: ET-150-12-1
Input: 120V / Output: 11.5v
Operating Frequency: 60 Hz
Load: 150 Watts max. / 10 Watts min.
Size: 4.03"(103mm) x 1.41"(36mm) x 1.06"(27mm)
MAT - Three Phase Auto Wound
For use with motor and other inductive loads. Both input and output voltages are tapped from a common winding rather than seperate coils as in double-wound (isolation transformers). Not recommended for use with electronic controls, DC equipment or computer applications.
For use with motor and other inductive loads. Both input and output voltages are tapped from a common winding rather than seperate coils as in double-wound (isolation transformers). Not recommended for use with electronic controls, DC equipment or computer applications.
MATS - Single Phase Auto Wound
For use with motor and other inductive loads. Both input and output voltages are tapped from a common winding rather than seperate coils as in double-wound (isolation transformers). Not recommended for use with electronic controls, DC equipment or computer applications.
For use with motor and other inductive loads. Both input and output voltages are tapped from a common winding rather than seperate coils as in double-wound (isolation transformers). Not recommended for use with electronic controls, DC equipment or computer applications.
Custom Distribution Transformers
Don't see what you're looking for?
Marcus can build what you need, usually within 7 days.
Contact us for for more information.
Don't see what you're looking for?
Marcus can build what you need, usually within 7 days.
Contact us for for more information.
Custom Industrial Control Transformers
Don't see what you're looking for?
Marcus can build what you need, usually within 7 days.
Contact us for for more information.
Don't see what you're looking for?
Marcus can build what you need, usually within 7 days.
Contact us for for more information.
EPC - Euro 50/60HZ Control Multiple Tap Open Type
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: Class F (155 deg c) (Type TPO 100 deg c)
Sound level: Less than 40 db
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: Class F (155 deg c) (Type TPO 100 deg c)
Sound level: Less than 40 db
RET-MAT - Three Phase Auto Wound Epoxy Encapsulate
Totally-Enclosed in epoxy resin for installation in areas with hazardous gases, dust and moisture. Designed for use in class 1, division 2 group A-D locations with a temperature classification of T3C, T4 and T5. Available with 4X stainless steel enclosures.
Totally-Enclosed in epoxy resin for installation in areas with hazardous gases, dust and moisture. Designed for use in class 1, division 2 group A-D locations with a temperature classification of T3C, T4 and T5. Available with 4X stainless steel enclosures.
EPO - Euro 50/60HZ Control Mulitiple Tap Closed Type
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: Class F (155 deg c) (Type TPO 100 deg c)
Sound level: Less than 40 db
Operating Frequency: 60 Hz (50 Hz available upon request)
Insulation: Class F (155 deg c) (Type TPO 100 deg c)
Sound level: Less than 40 db
Marcus Supreme ™ MHE - Marcus Supreme ™ High Efficiency
Marcus Supreme ™
Marcus Supreme generates a minimum of 33% less losses than the regulated standards (CSA C802.2 and NEMA TP-1) mandate and meets the most severe efficiency levels of the recommended DOE CSL-3. This translates into significant dollar savings for both rrtrofit and new installations.
Retrofits:
The replacement of an older, non-compliant transformer with a Marcus SupremeTM will result in savings in the total life cycle of the installations.
Example: Replacing a 45KVA loaded at 50% will result in a savings of $618 a year and of $18,450.00 over a 30 year period (based on $0.10 a KWH)
New Installations:
Choosing a Marcus SupremeTM over a new compliant transformer is the right decision.
Example: A 225KVA transformer Marcus MHE225A2 Supreme loaded at 75% will save $1557 a year and $46,710 over the 30 year life cycle of the transformer.
Marcus Supreme ™
Marcus Supreme generates a minimum of 33% less losses than the regulated standards (CSA C802.2 and NEMA TP-1) mandate and meets the most severe efficiency levels of the recommended DOE CSL-3. This translates into significant dollar savings for both rrtrofit and new installations.
Retrofits:
The replacement of an older, non-compliant transformer with a Marcus SupremeTM will result in savings in the total life cycle of the installations.
Example: Replacing a 45KVA loaded at 50% will result in a savings of $618 a year and of $18,450.00 over a 30 year period (based on $0.10 a KWH)
New Installations:
Choosing a Marcus SupremeTM over a new compliant transformer is the right decision.
Example: A 225KVA transformer Marcus MHE225A2 Supreme loaded at 75% will save $1557 a year and $46,710 over the 30 year life cycle of the transformer.
EUR-EX - Euro Export-Ready Transformers
Marcus Euro Export-Ready transformers are used to convert any standard 3 phase U.S. voltage to a standard 3 phase European voltage. This is useful when importing European machinery to the U.S. Additionally, these transformers when ordered in 50Hz can be connected in reverse to convert European power to U.S. power when importing U.S. machinery into Europe. Either way, these transformers are built to last, guaranteed!
Don't have floor space to mount your Euro Export-Ready transformer? No problem! Heavy duty wall mounting brackets are supplied on all Euro Export-Ready transformers up to 45KVA. Save your valuable floor space for your machinery instead of cluttering it with electrical equipment. When you wall mount this transformer in a warehouse, you no longer need to install concrete filled, steel barrier posts to protect the transformer from forklifts and other warehouse machinery.
Connections are made simple with Marcus’ Euro Export-Ready transformers. Jumpers are not necessary on the primary winding to change voltage because all voltages are brought to a solidly fixed terminal board for fast and easy connections. Dual taps are provided on the output board for 380 or 400volts Wye. Lugs are provided for easy and fast connection on the input and output side.
208 Volt Euro Export-Ready Transformers
208 volt input and 380 volt or 400 volt output
3 phase in either 60Hz or 50Hz
Nema1 Enclosure
240 Volt Euro Export-Ready Transformers
240 volt input and 380 volt or 400 volt output
3 Phase in Either 60Hz or 50Hz
Nema1 Enclosure
480 volt Euro Export-Ready Transformers
480 volt input and 380 volt or 400 volt output
3 phase in either 60Hz or 50Hz
Nema1 Enclosed
600 volt or 575 volt Euro Export-Ready Transformer
600 volt or 575 volt input and 380 volt or 400 volt output
3 phase in either 60Hz or 50Hz
Nema1 Enclosed
208 volt, 240 volt, 480 volt Euro Export-Ready Transformer
208v, 240v, 480v input and 380v or 400 volt outputs
3 phase in either 60Hz or 50Hz
Nema1 Enclosure
Marcus Euro Export-Ready transformers are used to convert any standard 3 phase U.S. voltage to a standard 3 phase European voltage. This is useful when importing European machinery to the U.S. Additionally, these transformers when ordered in 50Hz can be connected in reverse to convert European power to U.S. power when importing U.S. machinery into Europe. Either way, these transformers are built to last, guaranteed!
Don't have floor space to mount your Euro Export-Ready transformer? No problem! Heavy duty wall mounting brackets are supplied on all Euro Export-Ready transformers up to 45KVA. Save your valuable floor space for your machinery instead of cluttering it with electrical equipment. When you wall mount this transformer in a warehouse, you no longer need to install concrete filled, steel barrier posts to protect the transformer from forklifts and other warehouse machinery.
Connections are made simple with Marcus’ Euro Export-Ready transformers. Jumpers are not necessary on the primary winding to change voltage because all voltages are brought to a solidly fixed terminal board for fast and easy connections. Dual taps are provided on the output board for 380 or 400volts Wye. Lugs are provided for easy and fast connection on the input and output side.
208 Volt Euro Export-Ready Transformers
208 volt input and 380 volt or 400 volt output
3 phase in either 60Hz or 50Hz
Nema1 Enclosure
MODEL | MODEL | ||||
KVA | AMPS @ 208V | AMPS @ 380V | AMPS @ 400V | 60HZ | 50HZ |
3 | 8.3 | 4.6 | 4.3 | MT3H6-20 | MT3H6-20-EUR |
6 | 16.6 | 9.2 | 8.7 | MT6H6-20 | MT6H6-20-EUR |
10 | 28.0 | 15.2 | 14.5 | MT10H6-20 | MT10H6-20-EUR |
15 | 41.6 | 22.8 | 21.7 | MTH15H6-20 | MTH15H6-20-EUR |
30 | 83.3 | 45.6 | 43.4 | MTH30H6-20 | MTH30H6-20-EUR |
45 | 125.0 | 68.5 | 65.0 | MTH45H6-20 | MTH45H6-20-EUR |
50 | 139.0 | 76.0 | 72.3 | MTH50H6-2 |
MTH50H6-20-EUR |
75 | 208.0 | 114.0 | 108.4 | MTH75H6-20 | MTH75H6-20-EUR |
112.5 | 312.0 | 171.1 | 162.6 | MTH112.5H6-20 | MTH112.5H6-20-EUR |
150 | 416.0 | 228.2 | 216.8 | MTH150H6-20 | MTH150H6-20-EUR |
240 Volt Euro Export-Ready Transformers
240 volt input and 380 volt or 400 volt output
3 Phase in Either 60Hz or 50Hz
Nema1 Enclosure
MODEL | MODEL | ||||
KVA | AMPS @ 240V | AMPS @ 380V | AMPS @ 400V | 60HZ | 50HZ |
3 | 7.2 | 4.6 | 4.3 | MT3G6-20 | MT3G6-20-EUR |
6 | 14.4 | 9.2 | 8.7 | MT6G6-20 | MT6G6-20-EUR |
10 | 24.0 | 15.2 | 14.5 | MT10G6-20 | MT10G6-20-EUR |
15 | 36.1 | 22.8 | 21.7 | MTH15G15-20 | MTH15G6-20-EUR |
30 | 72.3 | 45.6 | 43.4 | MTH30G6-20 | MTH30G6-20-EUR |
45 | 108.0 | 68.5 | 65.0 | MTH45G6-20 | MTH45G6-20-EUR |
50 | 120.4 | 76.0 | 72.3 | MTH50G6-20 | MTH50G6-20-EUR |
75 | 181.0 | 114.0 | 108.4 | MTH75G6-20 | MTH75G6-20-EUR |
112.5 | 272.0 | 171.1 | 162.6 | MTH112.5G6-20 | MTH112.5G6-20-EUR |
150 | 360.0 | 228.2 | 216.8 | MTH150G6-20 | MTH150G6-20-EUR |
480 volt Euro Export-Ready Transformers
480 volt input and 380 volt or 400 volt output
3 phase in either 60Hz or 50Hz
Nema1 Enclosed
MODEL | MODEL | ||||
KVA | AMPS @ 480V | AMPS @ 380V | AMPS @ 400V | 60HZ | 50HZ |
3 | 3.6 | 4.6 | 4.3 | MT3B6-20 | MT3B6-20-EUR |
6 | 7.2 | 9.2 | 8.7 | MT6B6-20 | MT6B6-20-EUR |
10 | 12.0 | 15.2 | 14.5 | MT10B6-20 | MT10B6-20-EUR |
15 | 18.1 | 22.8 | 21.7 | MTH15B6-20 | MTH15B6-20-EUR |
30 | 36.1 | 45.6 | 43.4 | MTH30B6-20 | MTH30B6-20-EUR |
45 | 54.0 | 68.5 | 65.0 | MTH45B6-20 | MTH45B6-20-EUR |
50 | 60.2 | 76.0 | 72.3 | MTH50B6-20 | MTH50B6-20-EUR |
75 | 90.5 | 114.0 | 108.4 | MTH75B6-20 | MTH75B6-20-EUR |
112.5 | 136.0 | 171.1 | 162.6 | MTH112.5B6-20 | MTH112.5B6-20-EUR |
150 | 180.0 | 228.2 | 216.8 | MTH150B6-20 | MTH150B6-20-EUR |
600 volt or 575 volt Euro Export-Ready Transformer
600 volt or 575 volt input and 380 volt or 400 volt output
3 phase in either 60Hz or 50Hz
Nema1 Enclosed
MODEL | MODEL | |||||
KVA | AMPS @ 600V | AMPS @ 575V | AMPS @ 380V | AMPS @ 400V | 60HZ | 50HZ |
3 | 2.9 | 3.1 | 4.6 | 4.3 | MT3AO6-20 | MT3AO6-20-EUR |
6 | 5.8 | 6.0 | 9.2 | 8.7 | MT6AO6-20 | MT6AO6-20-EUR |
10 | 9.6 | 10.1 | 15.2 | 14.5 | MT10AO6-20 | MT10AO6-20-EUR |
15 | 14.4 | 15.1 | 22.8 | 21.7 | MTH15AO6-20 | MTH15AO6-20-EUR |
30 | 28.9 | 30.2 | 45.6 | 43.4 | MTH30AO6-20 | MTH30AO6-20-EUR |
45 | 43.2 | 45.2 | 68.5 | 65.0 | MTH45AO6-20 | MTH45AO6-20-EUR |
50 | 48.2 | 50.3 | 76.0 | 72.3 | MTH50AO6-20 | MTH50AO6-20-EUR |
75 | 72.1 | 75.4 | 114.0 | 108.4 | MTH75AO6-20 | MTH75AO6-20-EUR |
112.5 | 108.0 | 113.1 | 171.1 | 162.6 | MTH112.5AO6-20 | MTH112.5AO6-20-EUR |
150 | 144.0 | 150.8 | 228.2 | 216.8 | MTH150AO6-20 | MTH150AO6-20-EUR |
208 volt, 240 volt, 480 volt Euro Export-Ready Transformer
208v, 240v, 480v input and 380v or 400 volt outputs
3 phase in either 60Hz or 50Hz
Nema1 Enclosure
MODEL | MODEL | ||||||
KVA | AMPS @ 208V | AMPS @ 240V | AMPS @480V | AMPS @380V | AMPS @400V | 60HZ | 50HZ |
3 | 8.3 | 7.2 | 3.6 | 4.6 | 4.3 | MT3HGB6-20 | MT3HGB6-20-EUR |
6 | 16.6 | 14.4 | 7.2 | 9.2 | 8.7 | MT6HGB6-20 | MT6HGB6-20-EUR |
10 | 28.0 | 24.0 | 12.0 | 15.2 | 14.5 | MT10HGB6-20 | MT10HGB6-20-EUR |
15 | 41.6 | 36.1 | 18.1 | 22.8 | 21.7 | MTH15HGB6-20 | MTH15HGB6-20-EUR |
30 | 83.3 | 72.3 | 36.1 | 45.6 | 43.6 | MTH30HGB6-20 | MTH30HGB6-20-EUR |
45 | 125.0 | 108.0 | 54.0 | 68.5 | 65.0 | MTH45HGB6-20 | MTH45HGB6-20-EUR |
50 | 139.0 | 120.4 | 60.2 | 76.0 | 72.3 | MTH50HGB6-20 | MTH50HGB6-20-EUR |
75 | 208.0 | 181.0 | 90.5 | 114.0 | 108.4 | MTH75HGB6-20 | MTH75HGB6-20-EUR |
112.5 | 312.0 | 272.0 | 136.0 | 171.1 | 162.6 | MTH112.5HGB6-20 | MTH112.5HGB6-20-EUR |
150 | 416.0 | 360.0 | 180.0 | 228.2 | 216.8 | MTH150HGB6-20 | MTH150HGB6-20-EUR |